:::info Sample code
A working example is available on GitHub — [nodejs/plugin/adc](https://github.com/obniz/obniz/tree/master/examples/nodejs/plugin/adc).
:::

This section explains how to use the Analog-to-Digital Converter (ADC) on the obniz IO pins to measure analog voltage.

## Overview

By using the `ad.get(IO)` function, you can read the voltage applied to a specific IO pin as a numerical value. This is useful for retrieving data from analog sensors such as temperature, light, or pressure sensors.

## Function Description

### `ad.get(pin_number)`

* **Description**: Measures the voltage on the specified IO pin.
* **Parameters**:
* `pin_number` (number): The ID of the IO pin you wish to measure.


* **Return Value**:
* Returns the measured voltage in **Volts (V)**.

> From OS7.1.0, `ad.get()` also runs on obniz Board. The 10-bit ADC of the obniz Board and the 12-bit ADC of the ESP32 family are both scaled to volts internally, so the same code works across these products.

---

## Code Example

The following Lua script demonstrates how to continuously read the analog voltage from **IO Pin 1** and log it to the console.

```lua
-- This function runs repeatedly when the device is offline
function on_offline_loop()
  loop()
end

-- This function runs repeatedly when the device is online
function on_online_loop()
  loop()
end

-- Initialization
os.log(" - Lua Start");

-- Set Pin 1 to retain its state (keep it active for ADC)
io.retain(1, true);

-- Main Loop
function loop()
  -- Wait for 100ms to prevent excessive processing
  os.wait(100);
  
  -- Retrieve voltage from Pin 1 and log the value
  -- The value is returned in Volts (e.g., 1.25v)
  os.log("AD1: " .. ad.get(1) .. "v");
end

```

## Key Points

* **io.retain**: In this script, `io.retain(1, true)` is used to ensure the pin remains in a state where it can be measured consistently.
* **Polling Interval**: The `os.wait(100)` is included to manage the sampling rate. You can adjust this value depending on how frequently you need to monitor the sensor data.