> **Goal**  
> Understand the role of the Qwiic terminal on Intelligent Edge Kilo and how to connect to it.

* * *

## Overview

Intelligent Edge Kilo (Kilo) is equipped with a **Qwiic terminal for expansion**.  
In addition to connecting Qwiic and compatible devices, it can also be used as **digital IO** or **analog IN**.

## Wiring and Connection

> ❗
> You can connect sensors and communication cables even while Kilo is powered on.  
> However, **contact with metal parts or incorrect connection of the power lines may damage the equipment**.  
> Always check the voltage specifications of the device you are connecting, and work in a safe environment.

Connect a compatible Qwiic or Qwiic-compatible cable to the **"Qwiic" terminal** on the side of Kilo.

![Kilo Qwiic terminal](../images/51065705922841.png)

Qwiic-compatible devices mainly use **I²C communication**, allowing multiple devices to be connected on a single bus.  
You can use one or multiple Qwiic-compatible sensors and modules sold by various manufacturers.

![Qwiic connection example](../images/51065705924633.jpg)

The Qwiic terminal consists of 2 power lines and 2 signal lines. The signal lines are connected directly to the internal microcontroller and can each be used individually as **digital IO** or **analog IN**.

![Qwiic pin configuration diagram](../images/51065705926169.jpg)

| Pin | IO Function |
| --- | --- |
| 1 (black) | GND |
| 2 (red) | 3.3V output (supplied from Kilo) |
| 3 (blue) | IO1 / AD1 |
| 4 (yellow) | IO2 / AD2 |

### ⚫︎ Available Power

The Qwiic power line is shared with Kilo's internal power bus.  
The available current varies depending on Kilo's operating conditions.

-   Under normal operation (LTE-M connected, Wi-Fi/Bluetooth disabled), approximately **500mA** is available.
-   Because it varies depending on factors such as signal conditions, use approximately **100mA at most** as a guideline for safety.

> ⚠️
> -   If too much power is consumed, Kilo's internal protection circuit activates, shutting down the entire power line and causing a restart.

## Operation and Control

| Timing | Signal Line State |
| --- | --- |
| Immediately after startup | **Hi-Z (high impedance)**. The signal lines are disabled.  <br>After a restart, the previous state is **not retained**; the lines return to the state they were in after power-on. |
| After software configuration | Operates as **output／input／analog input** according to the configuration. |

* * *