## Overview

Intelligent Edge Kilo (Kilo) has a built-in **solid state relay (SSR)**.  
It can perform contact control of external devices and is used as a Form A (normally open) contact.

## Wiring and Connection

> ❗
> You can connect sensors and communication cables even while Kilo is powered on.  
> However, **contact with metal parts or incorrect connection of the power lines may damage the equipment**.  
> Always check the voltage specifications of the device you are connecting, and work in a safe environment.

Connect the device whose contact you want to control to the **"RELAY" terminal**, located in the same block as the power connector on the side of Kilo.

![Kilo RELAY terminal](../images/51065455637273.png)

The relay terminal is an **independent, isolated terminal** that is not connected to other terminals or the power lines.  
It can be used to switch a current path.

> ⚠️
> -   The **rated voltage is 60V or less**. It supports low-voltage contact control such as 24V PLCs.
> -   Be sure to check [“Relay Specifications”](../specifications/product-spec) on the specifications page, and pay attention to the allowable current and resistance values.

## Operation and Control

### ⚫︎ State at Startup

| Timing | Contact State |
| --- | --- |
| Immediately after power-on | **OFF (open)**. No current flows and the contact remains open.  <br>However, after a restart, the previous state is carried over. |
| Relay control enabled by software | If the setting is **ON**, the contact closes and current flows. |

### ⚫︎ Retention of ON／OFF State

Once set, the relay state is retained **until it is changed by software or the power is completely cut off**.  
As a result, the relay remains ON even in situations such as the following.

-   The internet connection is disconnected
-   The software or obnizOS restarts
-   The device enters sleep mode

If you want the relay to turn OFF automatically under these conditions, you can handle this with **device-side control via a plugin**.

* * *