Intelligent Edge Kilo (Kilo) has a built-in RS232 transceiver, enabling 12V communication rather than TTL. By wiring a DSUB9-pin connector, you can communicate directly.

## Wiring Method

Connect TX and RX to the "RS232/422/485" terminal on the side of Kilo.

The side labeled OUT is Kilo's TX (Kilo's output side), and the side labeled IN is Kilo's RX (the side Kilo takes input on).

**About GND**

There is no GND terminal for RS232 on the side panel. If the GND level of Kilo's power supply differs from that of the connected device, connect either the "-" side of Kilo's power section or the GND of the Qwiic terminal to the other device's GND.

**Termination Resistor**

On Kilo, the RS232/422/485 terminals are shared. If a pin for enabling the RS485 termination resistor is attached, TX and RX will be connected through 120 ohms, so please remove it.

### DSUB9-Pin Connection Example

As a wiring example, suppose you connect the following product:

[https://www.amazon.co.jp/dp/B0D9NVQKGB](https://www.amazon.co.jp/dp/B0D9NVQKGB)

The pin layout is as follows.

![](../images/51065084352537.png)

In this case, for a female head:

-   OUT: brown
-   IN: red

The photo below is an example of wiring that also includes GND (yellow).

![](../images/51065055890969.jpg)

Conversely, for a male head, it is reversed:

-   OUT: red
-   IN: brown

## About Startup

The RS232/422/485 terminal is not enabled during the startup phase and is in a Hi-Z state. No voltage is output from the TX side at the moment of power-on. Only when RS232 is enabled by software does the terminal become ready for input and output, and High is output from TX.

It is also equipped with an automatic power-saving feature. When enabled, output may not be applied unless voltage from the other device is detected. This kind of control depends on the software.

![](../images/51065055891481.png)